Research of characteristics slot-hole heat exchanger with the developed surface of heat exchange

  • E. C. Malkin Kiev National University of Construction and Architecture, Ukraine
  • Yu. E. Nikolaenko Ministry of Industrial Policy of Ukraine, Kyiv, Ukraine
  • M. I. Djachkov Taras Shevchenko National University of Kyiv, Ukraine
  • T. Yu. Nikolaienko Taras Shevchenko National University of Kyiv, Ukraine
Keywords: microprocessor, cooling system, slit heat exchanger, thermal conditions, electronics

Abstract

Thermal characteristics of multichannel slot-hole heat exchanger with the developed surface of heat exchange inside the opened-cycle water cooling system are experimentally investigated. Graphic dependences of average value of temperature of the simulator of a heat current and temperatures of the heat exchanger base are presented on tapped-off power. Dependences of tapped-off power and hydraulic losses on the of water consumption are given. It is shown, that use of developed slot-hole heat exchanger provides higher values of tapped-off power as compared to well-known two-channel slot-hole heat exchanger: at the temperature of heat-generating component simulator of +60°С the tapped-off power increases with 307 up to 750 W. Recommendations on increase of adaptability of slot-hole heat exchanger manufacturing are given. Heat exchanger is suitable for application in microprocessors and others heat-generating components and electronic equipment units cooling.

Published
2010-04-26
How to Cite
Malkin, E. C., Nikolaenko, Y. E., Djachkov, M. I., & Nikolaienko, T. Y. (2010). Research of characteristics slot-hole heat exchanger with the developed surface of heat exchange. Technology and Design in Electronic Equipment, (2), 36-39. Retrieved from https://www.tkea.com.ua/index.php/journal/article/view/TKEA2010.2.36