Wire radiator with heat pipes for computing equipment

  • L. A. Bulavin Taras Shevchenko National University of Kyiv, Ukraine
  • Т. Yu. Nikolayenko Taras Shevchenko National University of Kyiv, Ukraine
  • Yu. Е. Nikolayenko Taras Shevchenko National University of Kyiv, Ukraine
Keywords: wire radiator, heat pipe, computing equipment, microprocessor

Abstract

One approach to improving heat dissipation efficiency from computing components such as high-performance microprocessors is proposed. A prototype wire radiator was studied, consisting of copper wire with a diameter of 0.12 mm wound around a frame of two heat pipes, each 6 mm in diameter and 500 mm long. It was shown that the temperature drop along the heat pipe is nearly 60 times smaller than that of a solid copper rod and 200 times smaller than that of a copper tube of the same dimensions. The use of wire finning allowed the average temperature in the heating zone to be reduced by an additional one-third at a heater power of 49.2 W.

Published
2004-12-30
How to Cite
Bulavin, L. A., NikolayenkoТ. Y., & NikolayenkoY. Е. (2004). Wire radiator with heat pipes for computing equipment. Technology and Design in Electronic Equipment, (6), 29-31. Retrieved from https://www.tkea.com.ua/index.php/journal/article/view/TKEA2004.6.29