Influence of cyclic operating mode on the reliability of thermoelectric cooling devices

  • V. P. Zaikov Research Institute «Storm», Odesа, Ukraine
  • V. F. Moiseev Research Institute «Storm», Odesа, Ukraine
Keywords: cyclic mode, duty cycle, failure rate, reliability, switching frequency

Abstract

The paper examines the cyclic operating mode of thermoelectric cooling devices (TECs) and establishes the relationship between reliability indicators and key parameters. The derived correlations allow assessment of how a wide range of physical parameters influence the reliability of TECs working in cyclic mode compared to continuous operation.

Published
2003-12-30
How to Cite
Zaikov, V. P., & Moiseev, V. F. (2003). Influence of cyclic operating mode on the reliability of thermoelectric cooling devices. Technology and Design in Electronic Equipment, (6), 35-38. Retrieved from https://www.tkea.com.ua/index.php/journal/article/view/TKEA2003.6.35