Investigation of transfer functions and sensitivity of a radio measurement pressure transducer

  • V. S. Osadchuk Research Institute «Helium», Vinnytsia, Ukraine
  • A. V. Osadchuk Research Institute «Helium», Vinnytsia, Ukraine
  • G. I. Gavryluk Research Institute «Helium», Vinnytsia, Ukraine
  • N. L. Bilokon Research Institute «Helium», Vinnytsia, Ukraine
Keywords: radio measurement transducer, pressure, frequency, transfer function, sensitivity

Abstract

Based on a nonlinear equivalent circuit of the pressure transducer, whose operation is described using Kirchhoff’s equations, the transfer function and sensitivity equation were obtained. The maximum sensitivity of the radio measurement transducer (13.75 kHz/kgf/mm²) lies in the pressure range above 0.5 kgf/mm².

Published
2004-12-30
How to Cite
Osadchuk, V. S., Osadchuk, A. V., Gavryluk, G. I., & Bilokon, N. L. (2004). Investigation of transfer functions and sensitivity of a radio measurement pressure transducer. Technology and Design in Electronic Equipment, (6), 32-34. Retrieved from https://www.tkea.com.ua/index.php/journal/article/view/TKEA2004.6.32